Application research of air suspension centrifugal blower in energy saving and noise reduction in cement industry (2)

來(lái)源:admin 發(fā)布時(shí)間:2022-05-18 21:13:21 點(diǎn)擊數(shù):

2. Comparison of usage and performance of blowers for cement industry

In the entire operation of the cement industry, the common blowers are mostly Roots blowers and traditional centrifugal blowers, all of which are equipment with high energy consumption and high noise.

(1) Roots blower. Roots blower is a constant flow blower, which has the advantages of simple structure, strong work adaptability and low price, but its transmission part requires lubricating oil, and has the disadvantages of high energy consumption, high noise, large vibration and high maintenance costs. In the cement industry, it is commonly used in rotary kiln, kiln head primary air, raw meal storehouse and precalciner air supply.

(2) Traditional centrifugal fans. The traditional centrifugal fan is a constant pressure fan. It is divided into single-stage centrifugal and multi-stage centrifugal according to the number of impellers. The output air volume changes with the change of the pipeline or load during operation, and the wind pressure does not change much. It has high noise and stable wind pressure. , wide flow range and other characteristics, in the cement industry, it is often used in the kiln head and kiln tail chimney exhaust, coal mill exhaust, kiln tail high temperature fan, etc.


常用鼓風(fēng)機(jī)的性能比較(表1

Fan type

Roots blower

Multistage centrifugal blower

Single stage centrifugal fan

Air Suspension Centrifugal Blower

Compression method

Volumetric

centrifugal

centrifugal

centrifugal

Total Efficiency %

62

65

70

70

Air volume adjustment %

100

60-100

50-100

45-100

Noise/Db

100

95-100

90-95

85

vibration

Very big

Big

Big

none

Lubrication device

Lubrication system

Lubrication system

Lubrication system

none

maintenance

frequent maintenance

Regular maintenance

Regular maintenance

Change the air filter regularly

life/year

1-5

10

10

15

volume

Big

Big

Big

Small

Installation and Construction

Require


Need to be fixed on the ground

Soundproofing


Need to be fixed on the ground

Soundproofing


Need to be fixed on the ground

Soundproofing


No need to fix

No soundproofing required

price

Low

middle

Middle and high

high